Domestic valve leak detector performance high quality comparable to imported instruments

[China Instrument Network Instrument R&D] On June 27, with the help of an internally developed valve internal leakage detector, the localization project team of the Pipeline Science and Technology Research Center conducted the first inspection of the internal leakage of a 40-inch ball valve at the natural gas station. The test results show that the self-developed valve inner leakage detector is relatively quick and accurate to determine the inner leakage of large-diameter natural gas ball valves.

All-welded large-diameter ball valves are mainly used for long-distance oil and gas pipelines, entrance and exit stations, and receiving and dispatching of ball and other important parts. Once a failure occurs, it will have a great impact on the safe operation of the oil and gas station. The internal leakage is always in the process of the pipeline valve operation. Expose the most prominent problems. The traditional internal leakage detection of the valve is mainly determined by manual observation of the valve pressure or the determination of the internal leakage of the valve in the cavity, which cannot be quantitatively detected and the timeliness is poor.

With the help of the localization of key equipment for oil and gas pipelines, the Pipeline Science and Technology Research Center successfully developed an internal valve leakage detector that can detect the lower limit of valve leakage of 0.04 cubic meters per hour. It not only expanded the maximum valve size for endoleurance testing from 20 inches to 40 inches for the first time, but also extended the detection of valve inner leakage from a single ball valve to areas such as forced-seal valves, plug valves, etc., enabling customization of valve leakage detection. And specialization provides good technical support for the daily maintenance of maintenance personnel at the station site.

(Original title: Pipeline Technology Research Center successfully developed a valve leak detector)

Create broad space, fulfill wonderful splendor

Compared with the usual machine room, Small Machine Room Passenger Elevator adopts the reasonable civil engineering layout, the machine room covers the equal area as that of the well. It saves the machine room space, and reduces the outline influence from the machine room towards the constriction. It can adapt to the buildings which has special requirements towards the outline appearance. It not only cuts down the construction cost, but also be very helpful to excite the inspiration of the construction designers to create the artistic buildings one after another.


Energy Saving



Small Machine Room Passenger Elevator

Small Machine Room Passenger Elevator, passenger elevator cost, passenger elevator size

Shandong Bester Elevator Co., Ltd. , https://www.besterlift.com